-
Detector de fallas por ultrasonido
-
indicador de grueso ultrasónico
-
Indicador de grueso de capa
-
probador portátil de la dureza
-
detector del defecto de la radiografía
-
Los rastreadores de tuberías de rayos X
-
Detector de vacaciones
-
prueba de partícula magnética
-
Eddy Current Testing Equipment
-
Pruebas de penetración
-
Durómetro de orilla
-
probador brinell de la dureza
-
probador de la dureza de Rockwell
-
Probador micro de la dureza de Vickers
-
Prueba de dureza del material
-
metro de vibración
-
Prueba de rugosidad de la superficie
-
Proyector de perfil
-
Medidores de brillo
-
martillo concreto de la prueba
-
El termómetro láser infrarrojo
-
bobAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
-
WilliamAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
-
tomAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
-
LeoAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
Single-sided / double-site Vibration Meter With Dynamic Balancing
Lugar de origen | En Beijing |
---|---|
Nombre de la marca | HUATEC |
Certificación | ISO, CE, GOST |
Número de modelo | HG-7100 |
Cantidad de orden mínima | 1 piezas |
Detalles de empaquetado | Paquete estándar de exportación |
Tiempo de entrega | 1-4days |
Condiciones de pago | T/T, PayPal, Western Union |
Capacidad de la fuente | 500 piezas por mes |

Póngase en contacto conmigo para muestras y cupones gratis.
WhatsApp:0086 18588475571
En WeChat: 0086 18588475571
¿ Qué pasa?: sales10@aixton.com
Si tiene alguna preocupación, ofrecemos ayuda en línea las 24 horas.
xResaltar | vibration analyzer,digital vibration meter |
---|
Single-sided / double-site Vibration Meter With Dynamic Balancing
Function and Specification
1.Single-sided, double-site dynamic balancing function, can be used from hundreds of grams to tens of tons. Revolving speed from 1r/min to 180000r/min.
2. Balanced approach: test weight method and the influence coefficient method
3. Start-up times: Using the original installation conditions, open and down 2 to 3 times. Using the influence coefficient method one time can be obtained. So that achieving the balance correction and improve the efficiency.
4.Specialized test weight method, can evaluate the reasonable test weight quality according to the imputed data of rotor and actual field environment, which reduce start-up one time and improve the efficiency greatly.
5. Method of weight :Test weight method;Any angle method,The average weight method;Add slide method,Slide the slider method.
6. Wizard-style balancing operations: provide a comprehensive wizard-balancing function. Operator can carry out the dynamic balance correction step by step. It is very easy to use.
7. Humanized dynamic balance sequel function: If the dynamic balance process is interrupted by some reasons, can go on doing from the interrupted place, not from the starting.
8. Fast fault diagnosis function: Before the balance, can diagnose the rotor so that ensure the fault reason is that the dynamic balance negative, to avoid the blind balance. The function can be used to diagnose the common fault.
9. Vector decomposition: calculate the balance quality on vector decomposition and vector synthesis reasonably in order to meet the objective requirements of field installation.Vector decomposition: the quality of the solution calculated the reasonable balance of vector decomposition and vector synthesis, in order to meet the objective requirements of field installation
10. Improved balance report: After completing the balance process, the software can generate the dynamic balance report forms automatically and clear the basic information of rotor, the reducing situation of vibration and detailed test weight information.
11. Completed online help system. According to the specific examples, explain the operation steps and the possible problems in detail, so that it is easy to learn and use the software.
12. Rotate Speed Range: Standard Form:60~20000r/min
Low-speed :>1 r/min,
High-speed:>20000 r/min
13.Quality Range:Standard Form: >1KG Reinforced Type:>50g
14.Residual unbalance: Quality is 1mg,Vibration value:speed:0.01mm/s
15.One balance can make the unbalance reduce above 90%
16.Accuracy of vibration is 5 %
17.Accuracy of vector is 1%%
18.Software lifetime free upgrades, system lifelong maintenance
NO |
Item |
Qua |
Unit |
Model |
Remark |
1 |
Intelligent main body with two channels |
1 |
set |
|
|
2 |
Vibration acceleration sensor (including magnetic seat) |
2 |
piece |
|
30mv/g |
3 |
Special cable of vibration sensor |
2 |
rope |
|
5m |
4 |
Laser speed sensor |
1 |
piece |
|
5-200cm |
5 |
Special cable of laser speed sensor |
1 |
rope |
|
5m |
6 |
USB Cable |
1 |
rope |
|
|
7 |
Recharger |
1 |
set |
|
|
8 |
Reflective stripe |
1 |
piece |
|
|
9 |
Cassette of laser speed sensor |
1 |
set |
|
|
10 |
Electronic Scale |
1 |
set |
|
|
11 |
Software |
1 |
piece |
|
|
12 |
Manual |
1 |
set |
|
|
13 |
Certificate of soundness |
1 |
piece |
|
|
14 |
Packing Box |
1 |
set |
|
|
15 |
Packing List |
|
|
|
|
16 |
Laptop |
1 |
set |
|
|